Hampton 0.1毫米50号玻璃毛细管

Hampton 0.1毫米50号玻璃毛细管

货号:HR6-104
包装:25 pack

  • 英文名:0.1 mm Glass Number 50 Capillary
  • 品牌:Hampton
Hampton 0.1毫米50号玻璃毛细管

Hampton代理–金畔生物

硼硅玻璃50号毛细管壁厚0.01毫米,全长80毫米+ / – 5毫米。提供外径从0.1毫米到2毫米的毛细管,用于X射线数据收集,晶体密度测量和晶体生长实验。毛细管可以用蜡,环氧树脂等密封材料封闭,防止水分和气体。

应用

X射线数据采集

液-液扩散结晶

凝胶针状结晶

特征

50号硼硅玻璃

壁厚 10微米

描述

硼硅玻璃50号毛细管一端呈漏斗形,另一端封闭,壁厚0.01毫米,全长80毫米+/-5毫米,外径从0.1毫米到2毫米。可嵌入,盛放,储存小分子和生物大分子晶体用于X射线数据收集,晶体密度测量和晶体生长实验。毛细管可以用蜡,环氧树脂和其它密封材料密封,防止水分和气体。

请参照“线性吸收系数µcm-1表“,以决定适合的玻璃/石英玻璃毛细管。本表展示的是X射线数据收集时的辐射吸收量。

0.1mm至2.0mm毛细管开口端的基础尺寸为:3.0+/-0.15mm外径 x 0.13+/-0.10 mm壁厚,直径为在毛细管封闭端40毫米处的测量值。

 

货号

产品说明

公差

HR6-104

Size: 0.1 mm – 25 pack

0.1 mm -0.075 / +0.075 mm

HR6-106

Size: 0.2 mm – 25 pack

0.2 mm -0.050 / +0.050 mm

HR6-108

Size: 0.3 mm – 25 pack

0.3 mm -0.050 / +0.100 mm

HR6-110

Size: 0.4 mm – 25 pack

0.4 mm -0.100 / +0.100 mm

HR6-112

Size: 0.5 mm – 25 pack

0.5 mm -0.100 / +0.100 mm

HR6-114

Size: 0.6 mm – 25 pack

0.6 mm -0.100 / +0.100 mm

HR6-116

Size: 0.7 mm – 25 pack

0.7 mm -0.150 / +0.150 mm

HR6-118

Size: 0.8 mm – 25 pack

0.8 mm -0.150 / +0.150 mm

HR6-120

Size: 0.9 mm – 25 pack

0.9 mm -0.150 / +0.150 mm

HR6-122

Size: 1.0 mm – 25 pack

1.0 mm -0.150 / +0.250 mm

HR6-124

Size: 1.5 mm – 25 pack

1.5 mm -0.250 / +0.250 mm

HR6-126

Size: 2.0 mm – 25 pack

2.0 mm -0.250 / +0.250 mm

Hampton Polyethylene glycol 4,000

Hampton Polyethylene glycol 4,000

Applications
Crystallization grade Polyethylene glycol for formulating screens or for optimizatio
Features
Sterile filtered solution
Formulated in Type 1+ ultrapure water: 18.2 megaohm-cm resistivity at 25°C, < 5 ppb Total Organic Carbon, bacteria free (<1 Bacteria (CFU/ml)), pyrogen free (<0.03 Endotoxin (EU/ml)), RNase-free (< 0.01 ng/mL) and DNase-free (< 4 pg/µL)

Description
Polyethylene glycol 4,000
Synonym: PEG 4,000
H(OCH2CH2)nOH
Mr 3,500-4,500
CAS Number [25322-68-3]
EC Number 500-038-2
Merck 14,7568
RTECS TQ3500000
MDL Number MFCD00081839
PubChem Substance ID 24890217
Melting point (Starting Material) 58.0-61.0°C
Aldehyde None detected
Peroxide None detected

HR2-529 Measured pH range: 6.9 – 9.5 at 25°C
HR2-529 Measured Conductivity Range: 35.3 – 46.9 µS/cm at 25°C
HR2-529 Measured Refractive Index Range: 1.40172 – 1.40279 at 20°C

CAT NO NAME DESCRIPTION
HR2-605 Polyethylene glycol 4,000 Flake – 500 g
HR2-529 Polyethylene glycol 4,000 50% w/v solution – 200 ml

Hampton蛋白质结晶捞针(结晶环)18 mm Mounted CryoLoop™

Hampton蛋白质结晶捞针(结晶环)18 mm Mounted CryoLoop™

Applications

Cryocrystallography

Features

Adjustable loop orientation
Synthetic CryoLoop on adjustable stainless steel MicroTube
MicroTube specially engineered with EasySnap notches
20 micron diameter nylon CryoLoop

Description
Similar to the Mounted CryoLoop™ in design and function, the Adjustable Mounted CryoLoop allows one to manipulate and orient the CryoLoop to multiple, unique positions previously unattainable with typical cryo setups. The Adjustable Mounted CryoLoop is a 20 micron diameter synthetic loop mounted inside a malleable stainless steel sleeve, which in turn, is mounted inside the EasySnap MicroTube™.

Using a specially designed L-shaped tool (HR5-902) with a positioning notch, one can manipulate the angle and orientation of the CryoLoop by bending and adjusting the angle of the malleable stainless steel insert which holds the CryoLoop. The Adjustable Mounted CryoLoop may be positioned several times. Note: Repeated manipulation will fatigue the sleeve which can lead to failure of the sleeve. The Adjustable Mounted CryoLoop is designed to work with the CrystalCap System components.

The MicroTube is 24 mm in length and is specially engineered with EasySnap™ notches at the 10, 12, 14, 18, and 21 mm measures. To obtain the desired length of MicroTube, simply snap the MicroTube at the desired length and stake it to the CrystalCap™ Magnetic or CrystalCap™ Copper Magnetic. These nylon loops show minimal diffraction, are thin for fast freezing, strong, and aerodynamic.

Most data collection geometries prefer or require a 22 mm length between the base of the cap and the beam. For a 22 mm overall length using the CrystalCap, CrystalCap ALS, CrystalCap ALS HT and CrystalCap SPINE HT, snap the MicroTube at the second notch from the bottom, creating an 18 mm MicrozTube lenghth and secure to the CrystalCap using epoxy or similar adhesive. For a 22 mm over length using the CrystalCap Copper, CrystalCap Copper HT, CrystalCap ALS Copper HT snap the MicroTube at the fifth notch from the bottom (notch closest to the CryoLoop) and secure to the CrystalCap using epoxy or similar adhesive.

The HR5-902 Tool for Adjustable Mounted CryoLoop is not included with the Adjustable Mounted CryoLoop and must be purchased as a separated item.

18 mm Mounted CryoLoop™ - 20 micron

18 mm Mounted CryoLoop

18 mm Mounted CryoLoop™ - 20 micron

18 mm Mounted CryoLoop properly installed in a CrystalCap Magnetic

18 mm Mounted CryoLoop™ - 20 micron

Crystal in CryoLoop

CAT NO NAME DESCRIPTION
HR4-932 18 mm Mounted CryoLoop – 20 micron 0.025 – 0.05 mm – 25 pack
HR4-945 18 mm Mounted CryoLoop – 20 micron 0.05 – 0.1 mm – 25 pack
HR4-947 18 mm Mounted CryoLoop – 20 micron 0.1 – 0.2 mm – 25 pack
HR4-970 18 mm Mounted CryoLoop – 20 micron 0.2 – 0.3 mm – 25 pack
HR4-971 18 mm Mounted CryoLoop – 20 micron 0.3 – 0.4 mm – 25 pack
HR4-972 18 mm Mounted CryoLoop – 20 micron 0.4 – 0.5 mm – 25 pack
HR4-973 18 mm Mounted CryoLoop – 20 micron 0.5 – 0.7 mm – 25 pack
HR4-974 18 mm Mounted CryoLoop – 20 micron 0.7 – 1.0 mm – 25 pack
HR4-918 18 mm Mounted CryoLoop – 20 micron Sampler – 30 pack (5 of each diameter size 0.1 – 1.0 mm)

Hampton GRAS 1 • GRAS 2 Screens

Hampton GRAS 1 • GRAS 2 Screens

stallization screen for proteins, including monoclonal antibodies, where Polyethylene glycol is the primary, and Salt the secondary reagent, sampling pH 4-9
GRAS 1 • GRAS 2 ScreensGRAS 1 • GRAS 2 Screens Identify GRAS based reagents that promote crystallization of biotherapeutics for bioprocess, bioformulation, and continuous flow manufacturing applications
Features

Developed at Hampton Research
Generally Recognized As Safe reagent formulation
Samples pH 4.0 – 9.0 without an added buffer
Primary crystallization reagent:

GRAS Screen 1: PEG 300, 400, MME 550, & 600
GRAS Screen 2: PEG 1,000, MME 2,000, 3,350 & 4,000
Secondary crystallization reagent:

24 unique salts
Compatible with Vapor diffusion, microbatch, free interface diffusion
Reagents soluble between 4°C and 30°C

Description
GRAS Screen™ 1 and GRAS Screen™ 2 were developed by Hampton Research for the crystallization of proteins, including monoclonal antibodies. Each of the chemicals in GRAS Screen 1 and 2 have been used under one or more of the following categories. As (1) a Generally Recognized As Safe (GRAS) substance, (2) a pharmaceutical excipient, (3) a normal physiological constituent, (4) a metabolic byproduct, and/or (5) a Everything Added to Food in the United States (EAFUS) substance.

GRAS Screen 1 samples four low molecular weight Polyethylene glycols (300, 400, MME 550, and 600) versus twenty-four salts, encompassing pH 4-9. GRAS Screen 1 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 1 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.

GRAS Screen 2 samples four medium molecular weight Polyethylene glycols (1,000, MME 2,000, 3,350, & 4,000) versus twenty-four salts, encompassing pH 4-9. GRAS Screen 2 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 2 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.

CAT NO NAME DESCRIPTION
HR2-451 GRAS Screen 1 1 ml, Deep Well block format
Price Quantity
$245.00
CAT NO NAME DESCRIPTION
HR2-452 GRAS Screen 2 1 ml, Deep Well block format
Price Quantity
$245.00

Hampton晶体删选试剂盒

Hampton晶体删选试剂

1.Screens 晶体删选试剂盒

产品名称 货号 用途备注
Index Kit HR2-144 用于生物大分子结晶
CrystalScreen Kit HR2-110 用于蛋白质,核酸水溶性小分子结晶
Crystal Screen 2 Kit HR2-112
Pegrx 1 HR2-082 用于生物大分子结晶
Pegrx 2 HR2-084 用于生物大分子结晶
Peg/Ion Screen Kit HR2-126 用于生物大分子结晶
Peg/Ion 2 Screen™ HR2-098 用于生物大分子结晶
Saltrx Kit HR2-108 用于生物大分子结晶
Membfac Kit HR2-114 用于膜蛋白和溶解度有限的样品结晶
Crystal Screen Lite HR2-128 用于蛋白质,缩氨酸,核酸的结晶
Natrix Kit HR2-116 用于核酸和蛋白核酸复合物的结晶
Crystal Screen Cyro Kit HR2-122 用于蛋白质,可溶性缩氨酸,核酸和水溶性小分子的初次低温结晶
Nucleic Acid Mini Screen Kit HR2-118 用于核酸片段的结晶
Low Ionic Strength Screen HR2-120 用于完整单抗,单抗片段以及在低离子浓度下溶解度较低的样品结晶
Silver Bullet & Silver Bullet Bio HR2-078 用于生物大分子的初次和二次结晶
HR2-080
Peg/Tacsimate Ph5.8 Crystallization Reagent HR2-090
Peg/Tacsimate Ph 6.8 Crystallization Reagent HR2-092
Peg/Tacsimate Ph 7.8 Crystallization Reagent HR2-094
Additive Screen™ HR2-428 利用样品间和样品溶剂间相互作用来优化晶体生长和改变样品溶解度
产品名称 货号 用途备注
Detergent Screen 1 HR2-410 改善疏水作用引起的非特异性聚集
Detergent Screen 2 HR2-411
Detergent Screen 3 HR2-412
Detergent Screen HR2-408
Heavy Atom Screen Pt HR2-442 Heavy Atoms For Multiple Isomorphous Replacement
Heavy Atom Screen Au HR2-444
Heavy Atom Screen Hg HR2-446
Heavy Atom Screen M1 HR2-448
Heavy Atom Screen M2 HR2-450
I3c Phasing Kit HR3-133

2.Custom Shop Crystallization Reagents 结晶试剂盒中单独的试剂

  1. Optimize™ Reagents晶体生长条件优化试剂

⑴ Optimize™ – Polymers聚合体

⑵ Optimize™- Organics (Volatile) 挥发性有机物

⑶ Optimize™- Organics (Non-Volatile)非挥发性的有机物

⑷ Optimize™- Salts 盐类

⑸ Optimize™- Buffers缓冲液

⑹ Optimize™- Solubilizing Agents (NDSB) 溶解试剂NDSB

⑺ Optimize™ – Reducing Agent还原剂-TCEP氢氯化物

⑻ Optimize™ – Cryoprotectants

⑼ Optimize™ – Oils用于结晶的油类

⑽ Optimize™ – Silica Hydrogel硅胶

⑾ Optimize™ – LM Agarose低熔点琼脂糖
5.Crystallization Plates, Hardware & Accessories结晶耗材
⑴ 24 Well Crystallization Plates 24孔晶体板-分悬滴和坐滴两种
⑵ 48 Well Crystallization Plates 48孔晶体板
⑶ 72 Well Crystallization Plates72孔晶体板
⑷ 96 Well Crystallization Plates 96孔晶体板等

Hampton 24孔悬滴板 VDX Plate with sealant(带密封剂)

Hampton 24孔悬滴板 VDX Plate with sealant(带密封剂)
VDX Plate with sealant
Applications

Hanging drop crystallization
Sitting drop crystallization with Micro-Bridges® or Glass Sitting Drop Rods™
Dialysis crystallization with Dialysis Buttons™
Features

24 well plate with raised cover
Sealant applied to 24 wells, ready to seal with cover slides
Compatible with 22 mm diameter square and circle cover slides
Optically clear plastic
Extremely versatile and cost-effective crystallization platform
Compatible with UV crystal imaging when used with HR3-231 and HR3-233 – 22 mm x 0.22 mm Siliconized circle cover slides and HR3-215 and HR3-217 – 22 mm x 0.22 mm Siliconized square cover slides

Description
24 well crystallization plate for hanging drop or sitting drop vapor diffusion crystallization (when used with Micro-Bridges or Glass Rods), or dialysis crystallization (when used with Dialysis Buttons). Stackable, optically clear plastic 24 well plates with raised covers (to allow room for cover slides) and flat bottoms for exceptional optics. Raised, wide rings around each reservoir (well) minimize cross contamination and allow each well to be individually sealed with 22 mm diameter circle or square cover slides. Plates are individually wrapped and supplied with applied sealant. 15.0 cm x 10.8 cm plate footprint is convenient for manual pipetting and well access while at the same time compatible with some automated liquid handling systems. Approximate dimensions: 15.0 cm x 10.6 cm x 2.2 cm. Approximate well size: 1.7 cm x 1.6 cm. Typical well volume: 500 to 1,000 µl. Well capacity: 3.5 ml.

CAT NO NAME DESCRIPTION
HR3-172 VDX邃「 Plate with sealant 24 plate case
HR3-170 VDX邃「 Plate with sealant 100 plate case

Hampton 24孔坐滴板 Cryschem Plate

Hampton 24孔坐滴板 Cryschem Plate

Applications

 Sitting drop crystallization

  Heavy atom soaks

  Seeding

Features

Optically clear, concave sitting drop post
Cryschem Plate – Larger footprint and round reagent reservoir
Cryschem M – Microplate footprint with round reagent reservoir
Cryschem S – Microplate footprint with square reagent reservoir

Compatible with Formulatrix Formulator

Smooth, flat top for easy seal
Each plate supplied with a cover

Materials

  Optically clear polystyrene

 Description

The Cryschem Plate is a 24 well sitting drop plate that is sealed with clear sealing tape. The polystyrene plate is supplied with a raised cover so the plate can also be sealed with vacuum grease and plain glass or plastic cover slides (22 mm diameter). The stackable, 24 well plates have distortion-free, flat bottom wells and a concave sitting drop post in the center of the well for concentric equilibration of the drop with the reagent. Each plate is individually sealed. The top of the plate and each of the 24 wells is a single, flat plane for smooth and easy seal application. Well spacing provides for a large seal area between wells to prevent cross contamination and evaporation.

上海金畔生物作为Hampton蛋白结晶产品的代理商,竭诚为您服务,欢迎新老客户咨询。

Cryschem Plate is large plate footprint with circular reagent reservoir. Cryschem plate approximate size: 15.1 cm x 10.6 cm x 2.2 cm. Approximate well size: 1.6 cm x 1.5 cm. Typical fill volume: 500 to 1,000 µl. Well capacity: 1.5 ml. Maximum drop volume on post: 40 µl. Recommended seal: HR3-511 Crystal Clear Sealing Tape (1.88 inch x 43.7 yard roll, with cutter) or HR4-511 Crystal Clear Sealing Tape (1.88 inch x 60 yard roll, without cutter).

Cryschem M Plate is microplate footprint with circular reagent reservoir. Cryschem M microplate approximate size: 128 mm x 86 mm x 14 mm. Approximate circular reservoir size: 15 mm wide x 9 mm deep. Typical reservoir volume: 500 µl. Well capacity: 1.1 ml. Maximum drop volume on post: 30 µl. Recommended seal: HR3-609 Crystal Clear Sealing Film (100 pack), HR4-521 ClearSeal Film (100 pack) or HR4-506 Crystal Clear Sealing Tape (3 inch x 55 yard roll, without cutter). HR4-508 Crystal Clear Sealing Tape (0.75 inch x 650 inch, with cutter) seals a single row at a time.

Cryschem S Plate is microplate footprint with square reagent reservoir. Cryschem S microplate approximate size: 128 mm x 86 mm x 14 mm. Approximate square reservoir size: 15 mm wide x 9 mm deep. Typical reservoir volume: 500 µl. Well capacity: 1.1 ml. Maximum drop volume on post: 30 µl. Recommended seal: HR3-609 Crystal Clear Sealing Film (100 pack), HR4-521 ClearSeal Film (100 pack) or HR4-506 Crystal Clear Sealing Tape (3 inch x 55 yard roll, without cutter). HR4-508 Crystal Clear Sealing Tape (0.75 inch x 650 inch, with cutter) seals a single row at a time.

Cryschem Plate

Cryschem plate

CAT NO NAME DESCRIPTION
HR3-158 Cryschem Plate 24 plate case
HR3-160 Cryschem Plate 100 plate case
HR1-002 Cryschem M Plate (round reagent reservoir) 50 plate case
HR3-308 Cryschem S Plate (square reagent reservoir) 50 plate case

Sigma代理  Abcam代理  CST代理  Santa Cruz代理  Biolegend代理 ebioscience代理  Invitrogen代理   millipore代理  BD流式抗体代理   GeneTe x抗体代理  Novus抗体代理   R&D代理 Biovison代理  Jackson代理  MBL抗体代理  ProSpec抗体代理  Bethyl抗体代理  Antibody Revolution抗体代理  Torrey Pines Biolabs代理  Amresco代理  MPbio代理  Laysan bio代理  NANOCS代理  Avanti代理  wako代理  lumiprobe代理(活性荧光染料)   NEB酶代理  Roche酶代理  Toyobo酶代理   USP代理  EP代理  Dr代理  TRC代理  TCI代理  Reagecon代理 Megazyme代理 Hampton代理(蛋白结晶) whatman代理(滤膜滤纸) GE代理(蛋白纯化) Corning康宁代理  Axygen代理 Falcon代理  NISSUI日水代理 Himedia代理 OXOID代理  BD培养基代理 Ludger代理(糖蛋白分析产品)  Eppendorf代理  Labnet代理  标准品代理 抗体代理 酶试剂代理  培养基代理 耗材代理 Elisa试剂盒代理 。

Hampton结晶用缓冲盐试剂盒– SaltRx

Hampton结晶用缓冲盐试剂盒– SaltRx

SaltRx 1 • SaltRx 2 • SaltRx HT

Applications

Primary or secondary, salt and pH matrix crystallization screen for biological macromolecules

Features

Salt versus pH matrix crystallization screen
Samples pH 4 to 9
22 unique salts versus salt concentration and pH
Compatible with microbatch, vapor diffusion, liquid & gel diffusion methods
Tube or Deep Well block format
Preformulated, ready to screen
Developed at Hampton Research
All salts and buffers in screen readily available as Optimize™ reagents for reproducing and optimizing crystals
Individual reagents available through the Hampton Research Custom Shop
 Description
SaltRx was developed by Hampton Research as a primary and secondary, salt and pH based crystallization screen for biological macromolecules. Salt is the only primary crystallization reagent (precipitant) utilized. Based on a design of 96 conditions, the screen evaluates a broad portfolio of crystallization salts of varying concentration and pH. The selection, concentration, and pH of the salts were determined by data mining the BMCD1 and other crystallization databases, crystallization reports in the literature, and internal crystallization trials performed at Hampton Research. Based on this analysis, up to 35% of protein crystallizations involve salt as the primary crystallization reagent. SaltRx can be used as a primary crystallization screen when salt, ionic strength and pH are desired or suspected as appropriate crystallization variables. It is also useful as a secondary screen when salt only reagents/conditions from screens such as Index™, Crystal Screen™, and Grid Screen™ produce crystals and when further screening for additional salt conditions or optimization is desired. Since this screen does not contain volatile organics, it is compatible with microbatch, vapor diffusion, liquid and gel diffusion crystallization methods. SaltRx may also be used for dialysis crystallization in conjunction with Dialysis Buttons™.The original SaltRx kit (HR2-108) contained 96 unique reagents, 10 ml each. This kit has been discontinued and converted into two 48 reagent based kits, SaltRx 1 and SaltRx 2, available separately, which when used together are identical to the original SaltRx.SaltRx 1 contains 48 unique reagents, 10 ml each. SaltRx 1 contains reagents 1-48 of the original SaltRx 96 reagent kit.Salt Rx 2 contains 48 unique reagents, 10 ml each. SaltRx 2 contains reagent 49-96 of the original SaltRx 96 reagent kit.SaltRx HT contains the 96 SaltRx 1 and SaltRx 2 reagents in a single Deep Well block format.Ready-to-use reagents are sterile filtered and formulated with ultra-pure Type 1 water, using the highest purity salts, polymers, organics and buffers. Individual reagents are available through the Hampton Research Custom Shop.

Measured pH range of kit is 4.1 to 9.0 at 25°C
Average measured pH of kit is 6.9 at 25°C
Median measured pH of kit is 7.3 at 25°C
Mode measured pH of kit is 7.4 at 25°C

CAT NO NAME DESCRIPTION
HR2-136 SaltRx HT 1 ml, Deep Well block format
HR2-107 SaltRx 1 10 ml, tube format
HR2-109 SaltRx 2 10 ml, tube format

Hampton AlumaSeal™ II Sealing Film and Applicator

Hampton AlumaSeal™ II Sealing Film and Applicator

Applications

Sealing film used to reseal HT format screen kits in polypropylene blocks and plates

Features

Excellent seal
Film conforms to raised chimney wells
Easily pierceable with single or multichannel pipettors and robotic probes
Heat & cold resistant, recommended for temperatures from -80 °C to +120 °C
Certified DNase-, RNase-, and nucleic-acid-free
Less evaporation than clear films
Excellent barrier properties, virtually no reagent evaporation or drying
 Description
A 38 µm soft non-permeable aluminum foil sealing film with strong medical-grade adhesive, AlumaSeal II sealing films eliminate the need for heat-sealing devices or mats during the resealing of reagents in polypropylene deep well blocks. Each sealing film measures 82.6 x 142.9 mm and offers sufficient sealing area for 96 deep well blocks. Length between the perforations with end tabs removed is 125.4 mm. Compared to other aluminum foils, AlumaSeal II has less tendency to roll back on itself when removing the backing paper and it conforms well to the plate during application.AlumaSeal II is a soft, pierceable adhesive film designed for the convenient and rapid sealing of polypropylene deep well blocks. A multiple split backing with two end tabs allows for easy, accurate positioning and secure sealing. The use of an adhesive sealing film minimizes evaporation and helps to prevent well-to-well cross contamination in reagent blocks. AlumaSeal II films are easily pierced by pipettte tips or robotic probes or piercing tools for direct reagent recovery without significant gumming by adhesive.

AlumaSeal™ II Sealing Film and Applicator

AlumaSeal™ II Sealing Film and Applicator

CAT NO NAME DESCRIPTION
HR8-069 AlumaSeal II Sealing Film 100 pack
HR4-413 Film Sealing Paddle 5 pack

Hampton GRAS 5 • GRAS 6 Screens

Hampton GRAS 5 • GRAS 6 Screens

Applications

 GRAS reagent crystallization screen for proteins, including monoclonal antibodies, where Polyethylene glycol is the primary reagent, sampling pH 4.5 to 10

. Identify GRAS based reagents that promote crystallization of biotherapeutics for bioprocess, bioformulation, and continuous flow manufacturing applications

Features

Developed at Hampton Research
Generally Recognized As Safe reagent formulation
Samples pH 4.5 to 10; 8 unique buffers
Primary crystallization reagent:

GRAS 5: PEG 300, 400, MME 550, & 600
GRAS 6: PEG 1,000, MME 2,000, 3,350 & 4,000

 

Vapor diffusion, microbatch, free interface diffusion
Reagents soluble between 4°C and 30°C

Description

GRAS Screen™ 5 and 6 were developed by Hampton Research for the crystallization of proteins, including monoclonal antibodies. Each of the chemicals in GRAS Screen 5 and 6 has been used under one or more of the following categories. As (1) a Generally Recognized As Safe (GRAS) substance, (2) a pharmaceutical excipient, (3) a normal physiological constituent, (4) a metabolic byproduct, and/or (5) a Everything Added to Food in the United States (EAFUS) substance.

GRAS Screen 5 samples four low molecular weight Polyethylene glycols (300, 400, MME 550, and 600) at three concentrations versus eight unique buffers encompassing pH 4.5 to 10. GRAS Screen 5 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 5 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.

GRAS Screen 6 samples four medium molecular weight Polyethylene glycols (1,000, MME 2,000, 3,350, & 4,000) at three concentrations versus eight unique buffers encompassing pH 4.5 to 10. GRAS Screen 6 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 6 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.

Hampton Solubility & Stability Screen

Hampton Solubility & Stability Screen

Solubility & Stability Screen(溶解度和稳定性的屏幕)

应用:溶解性和稳定性屏幕的设计,以协助识别解决方案的条件,促进蛋白质的溶解性和稳定性,并尽量减少蛋白质沉淀。

Solubility & Stability Screen

Solubility & Stability Screen

Solubility & Stability Screen

Solubility & Stability Screen HR2-072

Applications

A solubility screen, a stability screen, an additive screen for protein assays including ThermoFluor and crystallization
Preformulation screening

 

Compatible with Thermofluor , Differential Scanning Fluorimetry (DSF), and Protein Thermal Shift assays
96 sterile filtered reagents
17 classes of reagents and excipients
Highly concentrated (10x) reagent formulation
Developed at Hampton Research

Features

Methodologies

Thermal shift assay
Dynamic Light Scattering
Use Solubility & Stability Screen along side Slice pH and Solubility & Stability Screen 2 to optimize sample buffer
Description

Solubility & Stability Screen is designed to assist in the identification of solution conditions which promote protein solubility and stability, and minimize protein precipitation. Solubility & Stability Screen is a solubility screen, a stability screen, and may also be used as an additive screen in the presence of a crystallization reagent.

The Hampton Research Solubility and Stability Screen can evaluate protein solubility, stability and crystallization in the presence of 94 different chemical additives sampling 17 different classes of reagents plus two controls.

Protein solubility and stability are universally required in a wide range of applications, including general biochemical studies, the preparation of proteins in pharmaceuticals, structural biology and crystallization.1-11The preparation of a concentrated, soluble and stable protein sample can often be a difficult task as proteins often aggregate, precipitate or denature.

Thermofluor (also known as Differential Scanning Fluorimetry, DSF and Protein Thermal Shift) provides a rapid, convenient and effective means of identifying subsaturating solution conditions that may also correlate with protein heterogeneity and poor crystallization outcomes.12

Protein solubility and stability is affected by many different chemical factors including pH, buffer type, chemical additives and excipients. pH and buffer type are dominant protein solubility and stability variables and can be evaluated and optimized using the Hampton Research Slice pH kit HR2-070. Slice pH evaluates protein solubility, stability and crystallization versus 20 different buffers over the pH range 3.5-9.6. Chemical additives influencing protein solubility and stability can be evaluated using the Solubility & Stability Screen.

It is widely accepted that protein solubility and stability can be increased by the use of chemical additives.5,15Seventeen classes of reagents are sampled by the Solubility & Stability Screen and each of these classes has been reported as important in improving sample solubility and stability.2-11

The Solubility & Stability Screen is a set of 94 high purity reagents formulated in high purity water (NCCLS/ASTM Type 1+) at 25°C and are 0.22 micron sterile filtered. The 94 solubility and stability reagents are formulated at 2 to 10 times their recommended working concentration. The remaining two reagents are water and a negative (TCA) control. A water control demonstrates the effect of diluting sample as well as sample buffer concentration. TCA, the negative control, demonstrates total sample precipitation, loss of sample solubility and loss of sample stability. The effects of the Solubility & Stability reagents can be compared with this negative control to assist in the identification of reagents promoting sample solubility and stability. 500 microliters of each reagent is supplied in a sterile 96 well polypropylene Deep Well block. The Solubility & Stability Screen reagents are compatible with the sitting or hanging drop vapor diffusion, microbatch, free interface diffusion, sandwich drop vapor diffusion, and dialysis crystallization methods utilizing water soluble reagents.

Hampton 膜蛋白结晶试剂 MembFac • Crystal Screen Lite • MembFac HT

Hampton  MembFac • Crystal Screen Lite • MembFac HT

Applications

Primary sparse matrix crystallization screen for membrane proteins and samples with limited solubility   膜蛋白和样品溶解度有限样品

Features

  Membrane protein sparse matrix screens

  Sparse matrix formula efficiently samples salts, polymers, organics and pH

  pH range 4.6 – 8.5

  Formulated for use with detergents

   Tube or Deep Well block format

   Crystal Screen Lite features a lower ionic strength than the original Crystal Screen

Description
MembFac is a highly effective sparse matrix screen specifically designed as a preliminary screen for the crystallization of membrane proteins. MembFac is based upon the highly effective biased sparse matrix methodology. The MembFac screen matrix is optimized for the crystallization of membrane proteins.

MembFac contains 48 unique reagent formulations. With this set of 48 conditions, numerous chemicals and chemical combinations are utilized, allowing one to evaluate a large variety of potential crystallization conditions. MembFac covers a broad pH range between 4 and 9.

The Rationale
The basic rationale of MembFac is to perform a sparse matrix screen while changing the detergent dimension because detergents play an important factor in the crystallization of membrane proteins. A MembFac screen is to be completed for each detergent. Detergent screens are available separately.

The Method
The membrane protein of interest is first isolated in the detergent which gives the highest stability and activity. The protein concentration should be approximately 10 to 20 mg/ml and the detergent concentration should be only slightly above the CMC. The sample is then set against MembFac, using all 48 solutions plus the screening detergent(s) of choice. The screening detergent concentration should be approximately one to three times the CMC. Hence, for each detergent screened, one would utilize approximately 1 to 2 mg of sample.

The MembFac protocol was used to crystallize membrane proteins including SQR, fumerate: quinone oxireductase, LHII, and LHCII.

Crystal Screen Lite is a sparse matrix of trial crystallization reagent conditions based upon the Crystal Screen™.3 The primary screen variables are salt, pH, and precipitant (salts, polymers, volatile organics, and non-volatile organics).2Crystal Screen Lite differs from the original Crystal Screen kit in that the primary precipitant reagents are one-half the concentration of that used in the original Crystal Screen formulation. The secondary salts, ions, and buffers remain at the original Crystal Screen concentration. Reducing the primary concentration of the primary precipitant results in a screen which is “more gentle” on the sample and typically produces much less precipitate conditions than the original Crystal Screen.

MembFac contains 48 unique reagents, 10 ml each.

MembFac HT contains 1 ml each of all 48 reagents from MembFac and reagents 1-48 from Crystal Screen Lite in a single Deep Well block format.

Ready-to-use reagents are sterile filtered and formulated with ultra-pure Type 1 water, using the highest purity salts, polymers, organics and buffers. Individual reagents are available through the Hampton Research Custom Shop.

CAT NO NAME DESCRIPTION
HR2-114 MembFac 10 ml, tube format
HR2-128 Crystal Screen Lite 10 ml, tube format
HR2-137 MembFac HT 1 ml, Deep Well block format

Hampton GRAS 3 • GRAS 4 Screens

Hampton GRAS 3 • GRAS 4 Screens

Applications

a.GRAS reagent crystallization screen for proteins, including monoclonal antibodies, where Salt is the primary, and Polyethylene glycol the secondary reagent, sampling pH 4-9

b.Identify GRAS based reagents that promote crystallization of biotherapeutics for bioprocess, bioformulation, and continuous flow manufacturing applications

Features

Developed at Hampton Research
Generally Recognized As Safe reagent formulation
Samples pH 4.0 – 9.0 without an added buffer
Primary crystallization reagent:

24 unique Salts

 

Secondary crystallization reagent:

GRAS Screen 3: PEG 300, 400, MME 550, & 600
GRAS Screen 4: PEG 1,000, MME 2,000, 3,350 & 4,000

 

Compatible with Vapor diffusion, microbatch, free interface diffusion
Reagents soluble between 4°C and 30°C

 Description
GRAS Screen™ 3 and GRAS Screen™ 4 were developed by Hampton Research for the crystallization of proteins, including monoclonal antibodies. Each of the chemicals in GRAS Screen 3 and 4 have been used under one or more of the following categories. As (1) a Generally Recognized As Safe (GRAS) substance, (2) a pharmaceutical excipient, (3) a normal physiological constituent, (4) a metabolic byproduct, and/or (5) a Everything Added to Food in the United States (EAFUS) substance.

GRAS Screen 3 samples twenty four salts, encompassing pH 4-9 versus four low molecular weight Polyethylene glycols (300, 400, MME 550, & 600). GRAS Screen 3 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 3 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.

GRAS Screen 4 samples twenty four salts, encompassing pH 4-9 versus four medium molecular weight Polyethylene glycols (1,000, MME 2,000, 3,350 & 4,000). GRAS Screen 4 is supplied in a 96 Deep Well block format and is compatible with robotic and multi-channel pipet liquid handling systems. GRAS Screen 4 is compatible with vapor diffusion, free interface diffusion, and microbatch crystallization methods. For research use only.

 

CAT NO NAME DESCRIPTION
HR2-453 GRAS Screen 3 1 ml, Deep Well block format
HR2-454 GRAS Screen 4 1 ml, Deep Well block format

Hampton Siliconized Glass Cover Slides

Hampton Siliconized Glass Cover Slides

ApplicationsHanging, sitting or sandwich drop crystallization
FeaturesHigh purity of glassSiliconized, hydrophobic glass surface0.22 mm & 0.96 mm glass thicknessThicker glass slides preserve temperature longer12 mm, 18 mm, & 22 mm glass diameterCircle & squareUV Compatible (>85% transmission)
12 x 0.22 mm Circle
18 x 0.22 mm Circle
22 x 0.22 mm Circle & Square

Description
Siliconized glass cover slides allow a droplet to be suspended in a position which provides near optimal conditions for vapor diffusion with the surrounding reservoir solution. These siliconized glass cover slides provide a consistent, high quality finish for crystallization experiments. The hydrophobic surface produces a drop which “stands well” and does not flatten on the glass. The siliconized surface prevents the adhesion of crystals and precipitate onto the glass surface. Use Dow Corning Vacuum Grease (HR3-510), Dow Corning 7 Release Compound (HR3-508), or immersion oil to seal cover slide to plate. Available in 12, 18 or 22 mm diameter circles and 22 mm diameter squares. Available in 0.22 mm or 0.96 mm glass thickness. The 0.96 mm thick slides are virtually unbreakable during crystallization handling.

The following slides are UV transmissable (>85%):
HR3-277 and HR3-279 – 12 mm x 0.22 mm Siliconized circle cover slides
HR3-231 and HR3-233 – 22 mm x 0.22 mm Siliconized circle cover slides
HR3-239 and HR3-241 – 18 mm x 0.22 mm Siliconized circle cover slides
HR3-215 and HR3-217 – 22 mm x 0.22 mm Siliconized square cover slides

图片

图片
Plain Glass Cover Slides
ApplicationsHanging, sitting or sandwich drop crystallization
Features
0.22 mm glass thickness
12 mm glass diameter
Hydrophilic glass surface
Circle & squareDescription
Plain, non-siliconized, hydrophilic glass cover slides. Useful for hanging drop, sitting drop, and sandwich drop vapor diffusion crystallization methods. The hydrophilic surface creates a drop which is more flat than a drop on a siliconized surface. This offers enhanced imaging for very small drops. Use Dow Corning® Vacuum Grease (HR3-510), Dow Corning® 7 Release Compound (HR3-508), or immersion oil to seal cover slide to plate.

HR3-209T 12 mm Plain circle cover slides for Tecan robot 5 oz case (~2,400 slides)

图片

图片
HR3-209T 12 mm Plain circle cover slides for Tecan robot 5 oz case (~2,400 slides)
PEN-VAC Kit
ApplicationsHolding and manipulating small, flat surfaces such as glass cover slides
FeaturesSelf-contained vacuumNo power neededCompactDescription
PEN-VAC is a great tool for handling small, flat surfaced objects such as plain and siliconized cover slides, as well as plastic slides. Simply depress the side button, touch the tip to the object to be lifted and release the button. PEN-VAC creates a totally self-contained vacuum that lifts up to 50 grams for up to one minute. Less than an ounce, the lightweight aluminum body fits in a pocket. No power supply needed. The kit includes one PEN-VAC with 5 3/4″ blue body, (3) angled and (3) straight probes with (2) each 1/8”, 1/4”, 3/8” diameter blue silicone vacuum cups . It is packaged in a clear plastic storage case.

图片
HR3-251  PEN-VAC Kit